HIOKI 3290 Clamp-On AC/DC HiTester All the Functions You Need for Measurement at DC or 1Hz and Up

Choice of three sensors (Example combinations)
3290/3290-10 +9691 : Measure up to 100A
3290/3290-10 +9692 : Measure up to 200A
3290/3290-10 +9693 : Measure up to 2000A

Choice of measurement methods
DC (for battery measurement)
AC+DC RMS (for full-/half-wave rectification measurement)
AC RMS (for current distortion measurement)
PEAK (for peak value measurement) of inrush current, etc.)

Choice of output (Simultaneous output)
Effective value output, frequency output, waveform output

3290-10 Functions
Current integral measurement
(obtain polarity-specific integrated DC values)
Operating time/duty measurement

Measurement method : DC, AC+DC (True RMS), AC (True RMS/ Average rectified)

Peak value display : Absolute value (of waveform peak)

Separate AC from DC output : Separate constituent element of AC, DC

Output (terminal 1) : Current waveform or true RMS value (2 V / setting range), Frequency value (1 VDC / setting range)

Output (terminal 2) : Rms current/Low-battery warning switch

Integral current measurement : None

Rate measurement : None

Timer settings : None

Data storage : None

Basic accuracy at DC current : 20.00/ 100.0A (using the 9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
20.00/ 200.0A (using the 9692 sensor) : ±1.3 % rdg. ±0.10 A/ ±0.5 A
200.0/ 2000A (using the 9693 sensor) : ±1.8 % rdg. ±1.0 A/ ±5 A

Basic accuracy at AC current
(45 to 66 Hz) 20.00/ 100.0A (using the 9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
20.00/ 200.0A (using the 9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
200.0/ 2000A (using the 9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A

Voltage measurement : None

Frequency measurement : 1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt.

Crest factor : 2.5 or later, or rated peak value of sensor

Frequency characteristic : DC, or 1 Hz to 1 kHz (accuracy guaranteed range)

At monitor output : based on the using sensor

Other functions : Selectable of responce time, filter (fc=550 Hz)

Power supply : LR6 (AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/-03 (The 3290-10 only: external power supply possible)

Dimensions, mass 155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz)

Supplied accessories : Carrying strap ×1, LR6 (AA) alkaline batteries × 4

HIOKI 3284 Clamp-On AC/DC HiTester Analysis for DC to distorted waves Analog output for current measuring level, current measuring waveform, or frequency measuring level. The peak hold fu...
HIOKI 3127-10 Clamp-On HiTester One meter drop-proof "Tested Tough !" Drop proof design withstands dropping from a height of 1 meter. Temperature measurement with optional Thermister prob...
HIOKI CM4371 AC/DC Clamp Meter is the best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. Model CM4371 is a 600A True RMS clamp meter that features...
HIOKI 3285-20 Clamp-On AC/DC HiTester AC/DC current measuring up to 2000 A Analog output for current measuring level, current measuring waveform, or frequency measuring level. The peak ho...
HIOKI 3286-20 Clamp-On Power HiTester Functionality and Safety Packed into a Handheld Unit Single phase 600 kW & up to 20th Harmonic levels measurement. Active/ reactive/ apparent power,...