Hioki PW3198 Power Quality Analyzer

HIOKI PW3198 Power Quality Analyzer New
  • Verify power problems in accordance with the IEC61000-4-30 Class A standard
  • Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz
  • Optional GPS BOX for synchronizing multiple devices

Product Details

HIOKI PW3198 Power Quality Analyzer The New World Standard for Power Quality Analysis, with recording & analyzing according to Class A requirements for PQAs

Verify power problems in accordance with the IEC61000-4-30 Class A standard. High Accuracy and continuous gapless recording (V:±0.1% of nominal voltage, A and W:±0.2% rdg. ±0.1% f.s.). CAT IV 600V - safe enough for incoming power lines. Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz. Wide dynamic range from low voltages up to 1300V (3P4W line-to-line voltage). Maximum 6000V transient overvoltage up to 700kHz. LAN, USB and SD card interfaces. Optional GPS BOX for synchronizing multiple devices.

Voltage can be measured with the main unit alone. An optional current sensor is necessary to measure current or power parameters. Use Model 9624-50 PQA-HiVIEW PRO (version 2.00 or later) with a PC to analyze the data collected to the SD card.

Measurement line type : Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel (must be synchronized to reference channel during AC/DC measurement)

Voltage ranges : Voltage measurement: 600.00 V rms

Transient measurement : 6.0000 kV peak

Current ranges : 500.00 mA to 5.0000 kA AC (depends on current sensor in use)

Basic accuracy : Voltage: ±0.1% of nominal voltage

Current : ±0.2% rdg. ±0.1% f.s. + current sensor accuracy

Active power : ±0.2% rdg. ±0.1% f.s. + current sensor accuracy

Measurement items :
1. Transient over voltage : 2MHz sampling.
2. Frequency cycle : Calculated as one cycle, 40 to 70Hz
3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle.
Current (1/2) RMS: half-cycle calculation.
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15
8. Frequency: Calculated as 10 or 12 cycles, 40 to 70Hz
9. 10-sec frequency: Calculated as the whole-cycle time during the specified 10s period, 40 to 70Hz
10. Voltage waveform peak, Current waveform peak
11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor (negative-phase, zero-phase)
12. High-order harmonic component (voltage/ current): 2kHz to 80kHz
13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50th orders
14. Harmonic voltage-current phase angle: 1th to 50th orders
15. Total harmonic distortion factor (voltage/ current)
16. Inter harmonic (voltage/ current): 0.5Hz to 49.5Hz
17. K Factor (multiplication factor)
18. IEC Flicker, ? V10 Flicker

Record : 55 weeks (with repeated recording set to [1 Week], 55 iterations) 35 days (with repeated recording set to [OFF])

Interface : SD/SDHC card, RS-232C, LAN (HTTP server funtion), USB2.0

Display : 6.5-inch TFT color LCD (640×480 dots)

Power supply : AC ADAPTER Z1002 (12V DC, Rated power supply 100V AC to 24 V AC, 50/60Hz)

BATTERY PACK Z1003 (Ni-MH 7.2V DC 4500mAh)

Dimensions, mass 300mm(11.81in)W × 211mm(8.31in)H × 68mm(2.68in)D (excluding protrusions), 2.6kg(91.7oz) (including battery pack)

Supplied accessories : Instruction manual×1, Measurement guide×1, VOLTAGE CORD L1000×1 set, Spiral Tube×1, Input Cable Labels×1, AC ADAPTER Z1002×1, Strap×1, USB cable (1m 3.28ft length)×1, BATTERY PACK Z1003×1, SD MEMORY CARD 2GB Z4001×1

Product Description

HIOKI PW3198 Power Quality Analyzer is the best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PW3198 is a power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated, and also for assessing power supply problems such as voltage drops, flicker, harmonics, and other electrical issues.

HIOKI 3194 Motor / Harmonic HiTester Up to 6 input channels for analysis of inverter motors and high-order harmonics. The 3194 provides Analysis of high-order harmonics up to the 3000th orde...
HIOKI 3390-10 Power Analyzer Maximizing the Efficiency of Energy Conversion Super precise ±0.1% accuracy model to meet the demanding needs of today. Switch from one range to another and s...
ELSPEC BLACKBOX Firmware Release. Class A: Extended support per latest 61000-4-30 Class A revision. Many new parameters, averaged intervals, and more! Device Configuration FILE: Based on X...
HIOKI 9625 Power Measurement Support Software Graphically process measurement data from Model 3169-20/21 easily on a PC Compatible devices : CLAMP ON POWER HiTESTER 3169-20, 3169-21, 316...
ELSPEC Investigator. Elspec Investigator is a client application that communicates, receives, and displays data from the PQSCADA server system . The communication performed uses a standard H...