Free Call Australia : 1 800 834 991

Related Products

Megger Resonating Inductor

MEGGER Resonating Inductor 
  • Expands the range of Capacitance and Dissipation Factor (Power Factor) Test Sets
  • Core gap gauge that displays position of inductor core & Hand-crank tuning wheel
  • Capable of tuning capacitances up to 1µF at 10 kV & Large wheels and handles for easy transport

Product Details

MEGGER Resonating Inductor

Expands the range of Capacitance and Dissipation Factor (Power Factor) Test Sets. Capable of tuning capacitances up to 1µF at 10 kV. Hand-crank tuning wheel. Core gap gauge that displays position of inductor core. Large wheels and handles for easy transport .

The Resonating Inductor is an accessory for use with the semi-automatic 12 kV Extended-Range Capacitance and Dissipation Factor Test Set, or the Automated Insulation Power Factor Test Set (DELTA-2000).

The Resonating Inductor is used to expand the capacitance range of these test sets and cannot be used with the standard 12 kV Capacitance and Dissipation Factor Test Set.

The Resonating Inductor is connected in parallel with the internal power supply of the test set. A manual tuning wheel on the Resonating Inductor varies the inductance to tune the parallel circuit for minimum load current.

When used with the semi-automatic 12 kV Extended-Range Capacitance and Dissipation Factor Test Set, or DELTA-2000, the Resonating Inductor will extend the short-time rating of the power supply from 200 mA to 4 A. This capacity is suitable for testing capacitance loads of up to 1 µF at 10 kV.

MEGGER Capacitance and Dissipation Factor Test Sets 2.5 kV and 12 kV Interference suppression circuits. Automatic dissipation factor balancing & Direct readout. These test sets automat...
MEGGER DELTA4000 Series 12 kV Insulation Diagnostic System Automatic and manual operation. Accurate and repeatable measurement results with high noise suppression. Lightweight, rugged two...
OMICRON CP RC Resonance Circuit for GIS Tester For HV testing OMICRON’s CPC 100 + CP RC are directly connected to the voltage transformer of the GIS, forming a resonance circuit. This rei...
OMICRON CP CU1 Multifunctional Coupling Unit for CPC 100 The CPC 100 + CP CU1 measure line impedances and k-factors on overhead lines and power cables. Ground impedances can also be deter...
WUHAN HUAYING HYGS Capacitance & Tan Delta Tester General introduction HYGS different frequency automatic dielectric loss tester is a high-precision instrument, which can be applied to...