Omicron CMIRIG-B Interface

OMICRON CMIRIG-B Interface 
  • Testing of wide area protection with IRIG-B functionality
  • Synchronization of the analog outputs of two or more CMC test sets
  • Generates an IRIG-B protocol and synchronizes other CMC test sets (slaves) at the same location

Product Details

OMICRON CMIRIG-B Interface

CMIRIG-B is an interface box enabling the connection of devices sending or receiving the IRIG-B protocol or PPS signals with CMC test sets. CMIRIG-B performs the level conversion between the CMC and the sources or receivers. The actual IRIG-B decoding and coding functionality is implemented in the CMC test set. CMGPS can optionally be used as source of a synchronizing trigger pulse or PPS signal.

Compatible test sets: CMC 356, CMC 353, CMC 256plus, CMC 850, CMC 256-6 with NET-1 Option

Applications

• Synchronization of the analog outputs of two or more CMC test sets with an external IRIG-B protocol or PPS signal. Example: End-to-end testing
• Testing of wide area protection with IRIG-B functionality using the IRIG-B time protocol generated by the CMC test set. Example: Testing of phasor measurement units (PMU). Supported standard (IRIG-B extension): IEEE C37.118 (Synchrophasor standard)
• Master/Slave Operation: A CMC test set (master) generates an IRIG-B protocol and synchronizes other CMC test sets (slaves) at the same location

Software modules supporting CMIRIG-B

• State Sequencer
• Pulse Ramping
• Advanced TransPlay
• Advanced Differential
• NetSim
• PQ Signal Generator
• EnerLyzer

OMICRON CMLIB A Connector CMLIB A is used for connecting the low level signal outputs of a CMC for measurement or controlling purposes. It can also be used to connect the inputs of a CMA ...
PONOVO PACB108 Optional Accessories The passive optical scanning head PACB108 detects the status of an LED. That can be an optical pulse output from an energy meter, the binary status of ...
PONOVO PGPS02 Optional Accessories It provides GPS synchronization signal in PPS (pulse per second) or PPM (pulse per minute) for synchronized test. Trigger time can be set for end-to-end...
OMICRON CMLIB B Interface Box The CMLIB B interface box provides additional connection terminals to support advanced test setups. It is used for tests with reference meters which require ...
MEGGER MGTR GPS Timing Reference Small and Lightweight. Easy to use Programmable Output Pulse for Synchronized end-to-end testing. 100 ns Accuracy within minutes of startup, 12-channel GP...